Anesthesia Workstation
Overview
Anesthesia Workstation
Anesthesia workstations are equipped with advanced monitoring systems that continuously assess the patient’s vital signs, including heart rate, blood pressure, and oxygen saturation, to ensure their well-being throughout the anesthesia process. The workstation also provides the anesthesiologist with real-time data and alerts, enabling them to adjust the anesthesia dosage and delivery to maintain the patient’s stability and comfort.
These workstations offer a wide range of ventilation modes, making it possible to provide mechanical ventilation to patients who are unable to breathe adequately on their own. This feature is particularly crucial during surgery when patients are under the effects of anesthesia and may not have the ability to breathe naturally.
About
Specifications
Technical Specification
DISPLAY SIZE : 10 inch
Available modes : VCV, PCV, VSIMV, PSIMV, CPAP
Patient type : Adult & Paediratric
Apnea backup : CPAP To VACV
Tidal volume : 40 To 1500 ml
PEEP : 0 To 30 cm H2O
Pressure Support : 1 To 50 cm H2O
Respiratory Rate : 7 To 60 bpm
Inspiratory Pressure Alarm : 5 To 40 cm H2O (High/Low Pressure Limit)
Inspiratory Time : 0.2 To 5.8 sec
I:E Ratio : 1:4 To 2:1
Trigger : 0.5 – 20 cm H2O
Rechargeable Li-ion Battery : Yes with up to 12 Hours back up
Keys to operate : Touch Display & Conrol Panel
Monitoring Parameters
Waveforms : P-T, F-T, V-T.
Parameters : Vt, Ppeak, PEEP, R.R, Minute Volume, FiO2, Pmean, Exp.time, Insp.time
General Specification
Dimension : 647.7mm*891.5 mm*1550mm
Power Supply : AC 110-240 +/- 10%, 50-60 Hz, 3-1.5 Amp.
Internal Battery Backup : 10 ~ 12 hrs.
Storage Drawer : 3
Caster Wheel : 4 wheels front 2 are lock wheels.
Pneumatic Specification
Pipeline supply (1.5 bar to 6 bar) : O2, N2O, Air
Operational Modes : Closed & Semi closed circuit System
Pressure Gauge : 7 Pressure Guage’s
High Pressure N2O – 2 nos
High Pressure O2 – 2 nos
Low Pressure O2 – 1 nos
Low Pressure N2O – 1 nos
Low Pressure Air – 1 nosN.F.W.D alarm : O2 and N2O failure alarm pressure below 1.5 bar.
N2O Cut Off : N2O will restricted with out O2 gas supply.
O2 flush : 35 ~ 75 L/min.
Rotameter : 5 Tube RotameterB.P.C Flow Meter : Yes
Alarms
Alarms :
FiO2 failure, drive gas Failure, High R.R,
Low R.R, Low FiO2, Sensor Failure, Expiratory Error,
Low Tidal Volume, Low patient/Patient Disconnected,
Low Battery, Low Minute Volume,
High Minute Volume, High Pressure,
High Tidal Volume.
Our Inhouse Products • Anesthesia Workstation • Transport Ventilator • ICU Ventilator
• Anesthesia Ventilator ВІРАР/СРАР
•
•
O2 Sedation System
FOREMOST MEDITECH with its delivery reach to almost all serviceable pin codes in India is continuously striving
for Product Excellence, Innovation. Precision and Perfection.
We are among the top 25 brands of ventilators in the world and the top most leading brand in India.